Calibration Zone
Coats 700 Wheel Balancer
Calibration Instructions

 

1. Turn the powers switch ON

2. Mount the test wheel to the machine

3. Enter the wheel parameters

4. If the machine is in ROUND OFF mode, toggle it OFF by pressing and holding the
SHIFT key and pressing ROUND OFF

5. If the machine is not in ounce mode put it into ounce mode by pressing and holding the
SHIFT key and pressing GM/OZ

6. Press and hold the SHIFT key and press CALIBRATE to enter the calibration mode.
The display should read CAL 0

7. Push the START button. The machine should now cycle. This cycle is referred to as the
zero spin cycle

8. The balancer should come up to speed, coast for several revolutions, and then brake to stop

9. The display should now read CAL 4

10. Position the wheel so the display for the Centre position LED for the outside (right) plane
is flashing

11. Add a 4 ounce weight to the 12 '0' clock position on the outside (right) of the wheel

12. Push the start button

13. The outer (right) weight display should read 4.00 +- 0.02 oz. and the Centre position
LED for the outside (right) plane should be flashing when the weight is at bottom dead Centre.

 